PRODUCTS

HOME > PRODUCTS > Other Series

Other Series

Product availability is subject to regulatory requirements. Please contact your local representative or Fujirebio Inc. Tokyo for further information.
Asterisk (*) means product with CE marking.

Espline® Series (Immunochromatography)


Other Tests

 

 

ESPLINE® Influenza A&B-N (10 tests)

Reagent for detection of influenza A & B virus antigens

Size
  • 10 tests / package
FEATURES & PRINCIPLE:

ESPLINE® Influenza A & B-N uses immuno-chromatography technology based on the principle of enzyme immunoassay. Both the influenza A virus antigen and influenza B virus antigen from nasal swab fluid, pharyngeal swab fluid, and nasal aspirate fluid can be detected by single test.

ESPLINE® Influenza A & B-N is a cassette-style reagent using a simple procedure without any special instrument.

STORAGE & SHELF LIFE:

Store at 1~30℃. Do not freeze.
Expiry date: 15 months after manufacturing

ESPLINE® TP* (20 tests)

Reagent for the detection of Toreponema pallidum antibodies

Size
  • 20tests / package
FEATURES & PRINCIPLE:

ESPLINE® TP is a product based on the principle of immuno-chromatography for detection of antibodies to Treponema pallidum (TP) in serum or plasma samples. The test kit employs two recombinant antigens that are considered to be the main antigens of TP. These recombinant antigens are fixed to a membrane in the test part of the cassette. An enzyme-labeled antigen pad, a substrate pad, and a developing solution are also included in the cassette.

STORAGE & SHELF LIFE:

Store at 2~10℃. Do not freeze.
Expiry date: one year after manufacturing

 

 

SFD HIV 1/2 (100 tests)

HUMAN IMMUNODEFICIENCY VIRUS TYPES 1 AND 2 ANTIBODY TEST
Particle-Agglutination Test for the Detection of Antibodies to Human Immunodeficiency Viruses type1 and/or type2 (HIV-1/HIV-2)

Size
  • 100 tests (qual.)
FEATURES & PRINCIPLE:

SFD HIV 1/2 is an in-vitro diagnostic test kit for the detection of antibodies to Human Immunodeficiency Viruses type1 and/or type2 (HIV-1/HIV-2) in human serum/plasma. This test is based on Fujirebio's particle-agglutination assay using gelatin particles coated with recombinant HIV-1 antigens (HIV-1/gp41 and HIV-1/p24) and HIV-2 antigen (HIV-2/gp36). These coated gelatin particles are agglutinated in the presence of HIV-1 and/or HIV-2 antibodies in human serum/plasma.

STORAGE & SHELF LIFE:

Store at 2~10℃. Do not freeze.
Expiry date : 18 months after manufacturing

Note:

With regard to marketing territories, please contact Fujirebio Inc., Tokyo.

ACE Color*(20 tests)

ANGIOTENSIN CONVERTING ENZYME TEST
Reagent Kit for the Colorimetric Measurement of Angiotensin Converting Enzyme (ACE)

Size
  • 20 tests
FEATURES & PRINCIPLE:

ACE Color is an in-vitro diagnostic test kit for the measurement of angiotensin converting enzyme (ACE) activity in human serum. This test is based on the colorimetric assay using a new substrate (p-hydroxybenzoyl-glycyl-L-histidyl-L-leucine). This test is extremely simple and has a good reproducibility compared with conventional assays for Serum Angiotensin Converting Enzyme (ACE). The concentration of quinoneimine dye is quantitatively measured at its absorbance maximum at 505 nm to evaluate the activity of ACE.

STORAGE & SHELF LIFE:

Store at 2~10℃. Do not freeze.
Expiry date : one year after manufacturing.

RAPIDIA® Auto HbA1c-L (20 mL X 1) (60 mL X 1)

HEMOGLOBIN A1C TEST
Latex-agglutination Test for the Measurement of Human Hemoglobin A1c

Size
  • 20 mL X 1
  • 60 mL X 1
FEATURES & PRINCIPLE:

RAPIDIA® Auto HbA1c is an in-vitro diagnostic test kit for the measurement of human hemoglobin A1c (HbA1c) in whole blood. The HbA1c level is measured by High-Performance Liquid Chromatography (HPLC), which is widely used to monitor diabetes mellitus patients. This test is based on the latex-agglutination assay and allows for the direct measurement of HbA1c concentrations without measuring total hemoglobin. This test provides results that correlate well with those of HPLC and that are not affected by labile HbA1c, such as carbamylated hemoglobin or acetylated hemoglobin.

STORAGE & SHELF LIFE:

Store at 2~10℃. Do not freeze.
Expiry date : one year after manufacturing.

IMMUDIA® - HemSp® (80 tests)

MICROTITER HEMAGGLUTINATION TEST
Reverse Passive Hemagglutination Test for the Detection of Human Hemoglobin

Size
  • 80 tests (qual.)
FEATURES & PRINCIPLE:

IMMUDIA®-HemSp® is an in-vitro diagnostic test kit for the detection of fecal occult blood (FOB). This test is based on the reverse passive hemagglutination assay using chicken-erythrocytes coated with antibodies to human hemoglobin. These coated chicken-erythrocytes are agglutinated in the presence of hemoglobin in human fecal samples. This test can detect human hemoglobin with similar sensitivity, specificity and titer to the conventional Fecal Occult Blood Test (FOBT), and involves no restrictions on dietary or drug intake for the patient. This test can detect human hemoglobin in amounts as low as100-200 μg/g stool.

STORAGE & SHELF LIFE:

Store at 2~10℃. Do not freeze.
Expiry date : one year after manufacturing.

Adiponectine:For Research Use Only.

High-Molecular Weight Adiponectin Determination Kit

Size
  • 96 tests
FEATURES & PRINCIPLE:

The test principle is based on a two-step sandwich enzyme immunoassay using anti-adiponectin monoclonal antibody. For determination, a specimen is initially made to react with monoclonal antibody fixed in test wells of a micro plate.
High-molecular weight adiponectin (3 x tetramer and 3 x hexamer) can be mainly determined
among that forming multimer in human blood.

STORAGE & SHELF LIFE:

Store at 2~10℃. (a set of standard solutions, packed separately, should be stored at -10゚C)
Expiry date: 10 months after manufacturing.

PAGE TOP

Miraca Holdings